Multi Column Distillation Plant Specification

  • Usage & Applications
  • Purification of water, Pharmaceutical industries, Hospitals, Laboratories, Biotechnology, Electronics, Research Institutes
  • Features
  • GMP compliant, High purity output, Sanitary construction, Energy efficient, Easy to maintain
  • Phase
  • Single Phase / Three Phase
  • Frequency
  • 50 Hz / 60 Hz
  • Temperature
  • Ambient to 100C (process dependent)
  • Noise Level
  • Low (<70 dB)
  • Type
  • Multi Column Distillation Plant
  • Material
  • Stainless Steel (SS 304 / SS 316 as per requirement)
  • Capacity
  • 50 LPH to 5000 LPH (custom capacities available)
  • Computerized
  • Yes (Optional/Customizable)
  • Control Mode
  • Automatic / Semi-Automatic
  • Voltage
  • 220V / 380V / 415V (as per requirement)
  • Power
  • 3 kW - 50 kW (depending on size and capacity)
  • Weight (kg)
  • 550 Kg to 3500 Kg (as per model)
  • Dimension (L*W*H)
  • Custom / As per specification
  • Color
  • Metallic Silver/Steel Finish
  • Surface Finish
  • Electropolished / Mirror finish (GMP standards)
  • Pressure
  • Atmospheric to 2 bar (as per design)
  • Feed Water Quality
  • Raw, RO, De-mineralized
  • Documentation
  • Validation & qualification documents provided
  • Cooling Type
  • Inbuilt Condenser System
  • Safety Features
  • Over temperature/pressure protection, Dry run protection, Level sensors
  • Drainage System
  • Automatic / Manual drainage system
  • Automation
  • PLC based control (as per request)
  • Number of Columns
  • 3 to 7 (as required)
  • Output Conductivity
  • Less than 1 S/cm
  • Condensate Quality
  • Meets IP/BP/USP standards
  • Utility Required
  • Electricity, Cooling Water, Feed Water
  • Cleaning System
  • CIP (Clean-In-Place) provision
  • Installation Type
  • Skid Mounted / Floor Mounted
 

Multi Column Distillation Plant Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About Multi Column Distillation Plant



Unlock a heroic deal with our Multi Column Distillation Plant-a top-tier solution trusted by venerable pharmaceutical giants and research institutes. This select, skid-mounted or floor-mounted system offers 3 to 7 columns (as required), inbuilt condenser, and robust PLC-based automation. Enjoy GMP-compliant electropolished surfaces, atmospheric to 2-bar pressure, and automatic/manual drainage. Engineered in stainless steel (SS 304/316), capacities range from 50 to 5000 LPH. Achieve less than 1 S/cm output conductivity, with complete safety and documentation. A true bargain for those demanding purity, efficiency, and unmatched reliability.

Superior Advantages and Uses

The Multi Column Distillation Plant provides a compelling advantage for pharmaceutical, biotech, electronics, and research sectors, delivering consistently pure water for crucial applications. The top competitive advantages include rapid start-up, minimal maintenance, energy efficiency, and GMP-compliant sanitary design. Used extensively for producing IP/BP/USP-grade distilled water, these systems meet the strictest standards for hospitals and laboratories alike, making them an essential investment for any setting demanding high-purity water.


Export Markets, Delivery, and Payment Terms

Serving a wide domestic market and global clientele, our Multi Column Distillation Plants are dispatched to countries worldwide, including Asia, the Middle East, Africa, and Europe. We provide reliable estimate-based delivery times tailored to each order's specifications and destination. Flexible payment terms are available, ensuring a smooth procurement process. Our efficient logistics enable prompt delivery-both within India and internationally-positioning us as a trusted manufacturer and supplier for diverse industrial requirements.


FAQ's of Multi Column Distillation Plant:


Q: How does a Multi Column Distillation Plant ensure high-purity water output?

A: The plant utilizes multiple distillation columns, advanced automation, and electropolished surfaces to remove impurities, producing water that meets stringent IP, BP, and USP standards. Integrated safety features and quality materials further guarantee consistent purity.

Q: What types of feed water can be processed using this system?

A: Our Multi Column Distillation Plant is capable of handling raw, reverse osmosis (RO), and de-mineralized feed water, adapting seamlessly to diverse source qualities while ensuring output conductivity of less than 1 S/cm.

Q: When should the plant's clean-in-place (CIP) system be used?

A: The CIP system should be operated according to your standard maintenance schedule or whenever cleaning is necessary to maintain optimum system performance. Automated or manual options make this process simple and efficient.

Q: Where are these distillation plants commonly installed?

A: They are widely installed in pharmaceutical industries, hospitals, laboratories, biotechnology companies, electronics manufacturing units, and research institutes needing high-purity water.

Q: What is the process for installation and what are the mounting options?

A: Installation can be done as either skid-mounted or floor-mounted, according to your facility's requirements. Comprehensive validation and qualification documentation support a seamless setup process.

Q: How does automation improve the plant's operation and safety?

A: PLC-based control systems manage all key functions, offer precise monitoring, and trigger protective actions if issues such as over-temperature, over-pressure, or dry run are detected, ensuring safe and reliable operation at all times.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pharmaceutical Machinery Category

Vacuum Leak Test

Vacuum Leak Test

Minimum Order Quantity : 1 Unit

Phase : Single/Three Phase

Frequency : 50/60 Hz

Material : Stainless Steel

Capacity : Custom/Variable Depending on Model

Computerized : Yes

Injectable Tank

Injectable Tank

Minimum Order Quantity : 1 Unit

Phase : Three Phase

Frequency : 50/60 Hz

Material : Stainless Steel (SS 316/304)

Capacity : 1001000 Liters (Customizable)

Computerized : Yes

Super Heated Water Spray Sterilizer

Super Heated Water Spray Sterilizer

Minimum Order Quantity : 1 Unit

Phase : Three Phase

Frequency : 50/60 Hz

Material : Stainless Steel

Capacity : 5002000 Litres (customizable)

Computerized : Yes

Ointment Cream Manufacturing Plant

Ointment Cream Manufacturing Plant

Minimum Order Quantity : 1 Unit

Phase : Three Phase / Single Phase (as required)

Frequency : 50 Hz / 60 Hz

Material : Stainless Steel (SS 304/316)

Capacity : 50 L to 1000 L (customizable)

Computerized : Other, Optional/Available